Jelajahi Sumber

Switched a logical OR to correct AND on conditional GET checks - fixes ZF-7482

git-svn-id: http://framework.zend.com/svn/framework/standard/trunk@17390 44c647ce-9c0f-0410-b52a-842ac1e357ba
padraic 16 tahun lalu
induk
melakukan
fba29d0d23
1 mengubah file dengan 1 tambahan dan 1 penghapusan
  1. 1 1
      library/Zend/Feed/Reader.php

+ 1 - 1
library/Zend/Feed/Reader.php

@@ -244,7 +244,7 @@ class Zend_Feed_Reader
                 }
             }
             $response = $client->request('GET');
-            if ($response->getStatus() !== 200 || $response->getStatus() !== 304) {
+            if ($response->getStatus() !== 200 && $response->getStatus() !== 304) {
                 require_once 'Zend/Feed/Exception.php';
                 throw new Zend_Feed_Exception('Feed failed to load, got response code ' . $response->getStatus());
             }